? MONT71 Elevator Integrated Controller ,Shenzhen Hpmont Technology Co., Ltd.Shenzhen Hpmont Technology Co., Ltd.

91嫩草国产线观看免费无码_中文字幕乱码视频日韩欧美_亚洲欧美成人在线_在线观看成人影院_色又黄又爽18禁免费网站_最新福利一区二区在线观看_国产一级黄色视频卡片_国产亚洲欧美东京日韩_国产精品无码免费视频_久久高清成人免费电影

Product Center
MONT71 Elevator Integrated Controller
MONT71 adapts complete parallel modes for signal transmission and meets needs of all villa and freight elevators. 1 phase 200 - 240V……2.2 - 3.7kW 3 phase 200 - 240V……3.7 - 30kW 3 phase 380 - 460V……5.5 - 45kW
  • Product features
  • parameters
  • Data download
  • Related accessories


Direct stop technology

Based on the distance control, the direct stop technology realizes smooth speed curve and high operating efficiency.

The elevator operation can automatically generate N curves and achieve high efficiency even no setting elevator speed parameters.


Complete parallel communication mode

All are built-in complete parallel communi-cation mode, and have optional serial communication.


Support the debugging via Bluetooth phones


Automatic identification grid voltage technology

Automatically correct the operation curve of elevator in accordance with the input grid voltage.


Multiple functions

There are 24 button I/O interfaces, which can meet the needs of 8 floors full selective even without expansion.

There are 24 relay outputs and 10 independent common outputs.

Via the function parameters, you can flexibly set the elevator control functions up to 54 kinds.

You can flexibly define functions of 24 digital inputs and outputs, and choose high or low level input.


Onboard small panel design

Design with three digital tubes and three keys.

Can display the fault, floors and other information, fault reset, shaft self-learning, call elevator and other operations.

Make easier for debugging and maintaining the elevator.


Flexible installation

The main control board can be directly installed on MONT71, and also can be installed on other locations.


Perfect protection for fault

Quick positioning method for fault based on fault subcode.

60 kinds of faults sub-level treatments.

Immediately locking the base electrode and switching off IGBT output at fault can avoid contactor arcing, which can ensure the elevator safe and reliable operation.

The cosine encoder wiring mode and encoder disconnection can be identified automatically.


Three high voltage inputs of 110 - 220V AC/DC

The main control board has three programm-able high voltage inputs of 110  -  220V AC/DC, which can reduce the system cost.


Smooth S-curve of acceleration and deceleration 

The optimized S-curve of acceleration and deceleration can make passengers have a good sense of comfort.


 



  • 1970-01-01
Share:
Related products